APC Smart-UPS 2200VA RM 2U LCD 120V
APC Smart-UPS, 1980 Watts / 2200 VA,Input 120V / Output 120V, Interface Port USB, Rack Height 2 U
Includes: CD with software, Documentation CD, Installation guide, Rack Mounting support rails, Smart UPS signalling RS-232 cable, USB cable
Looking for Better Pricing? Please Contact Us for help!
Sorry, this product is no longer available, please contact us for a replacement.
More pricing below, click here!
Over 20 million units sold - the UPS you can trust
APC award-winning Smart-UPS® is the most popular UPS in the world for servers, storage and networks. Trusted to protect critical data and equipment from power problems by supplying clean and reliable network-grade power. In addition to legendary reliability and manageability, Smart-UPS have extremely high efficiency at low, medium and high load levels making them ideal for today’s multi-core or virtualized servers that have varying load consumption. Available in a variety of form factors (tower, rack mount, rack/tower convertible) there is a model for every application and budget. Rack mounted Smart-UPS are ideal for powering Blade or density optimized servers in a distributed power protection environment as the primary or redundant protection. Smart-UPS® models have long been considered the benchmark for all network and server UPS's. Smart-UPS feature a 16-segment LED display, extended range automatic voltage regulation (AVR), and pure sine wave output on battery. Additional manageability options are available through the Smart-Slot interface, which is an internal slot for the installation of optional accessory cards. The extended run Smart-UPS XL has the capability to add external battery packs to scale runtime from minutes to hours typically needed for converged voice and data networks. The entry level Smart-UPS SC is an economical choice for small and medium businesses looking to protect small switches, networking devices and point-of-sale (POS) equipment.
SMT2200RM2U Feature Overview:
- Intuitive LCD interface - Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
- Predictive replace battery date - Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
- Green mode - Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
- Energy meter - Provides actual kilowatt hours of usage for energy conscious users.
- Wide Input Voltage Window - Saves your battery power for when you really need it - during power cuts!
- Outlet group control - Turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).
- Sequenced shutdown and restart - Configure select outlet groups to shut down and turn on in a pre-determined order (for UPSs with switched outlet groups).
- Audible alarms - Provide notification of changing flywheel conditions
- Pure sine wave output on battery - Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
- Single switched outlet group - Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
- Battery failure notification - Provides early-warning fault analysis on batteries enabling timely preventive maintenance
- Sequenced start-up - Power on select outlet groups in a defined sequence.
- High online efficiency - Reduces utlility costs, generates less heat.
- Cold-start capable - Provides temporary battery power when the utility power is out.
- Serial Connectivity - Use any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.
- Hot-swappable batteries - Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- Disconnected battery notification - Warns when a battery is not available to provide backup power.
- Automatic self-test - Periodic battery self-test ensures early detection of a battery that needs to be replaced.
- Automatic restart of loads after UPS shutdown - Automatically starts up the connected equipment upon the return of utility power.
- Adjustable voltage-transfer points - Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
- Adjustable voltage sensitivity - Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
- Audible alarms - Provides notification of changing utility power and UPS conditions.
- User-replaceable batteries - Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
- Serial Connectivity - Provides management of the UPS via a serial port.
- USB connectivity - Provides management of the UPS via a USB port (not available on all models).
- Temperature-compensated battery charging - Prolongs battery life by regulating the charge voltage according to battery temperature.
- Boost and Trim Automatic Voltage Regulation (AVR) - Gives higher application availability by correcting low and high voltage conditions without using the battery.
- Intelligent battery management - Maximizes battery performance, life, and reliability through intelligent, precision charging.
- Safety-agency approved - Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
- Network manageable - Provides remote management of the UPS over the network.
- Frequency and voltage regulation - Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
- Adjustable voltage sensitivity - Provides the ability to adapt the Power Conditioner for optimal performance in specific power environments or generator applications.
- Predicitive failure notification - Provides early-warning fault analysis ensuring proactive component replacement.
Features & Benefits:
Availability | |
Boost and Trim Automatic Voltage Regulation (AVR) | Gives higher application availability by correcting low and high voltage conditions without using the battery. |
Intelligent battery management | Maximizes battery performance, life, and reliability through intelligent, precision charging. |
Power conditioning | Protects connected loads from surges, spikes, lightning, and other power disturbances. |
Temperature-compensated battery charging | Prolongs battery life by regulating the charge voltage according to battery temperature. |
Automatic restart of loads after UPS shutdown | Automatically starts up the connected equipment upon the return of utility power. |
Automatic self-test | Periodic battery self-test ensures early detection of a battery that needs to be replaced. |
Disconnected battery notification | Warns when a battery is not available to provide backup power. |
Manageability | |
Network manageable | Provides remote management of the UPS over the network. |
Audible alarms | Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition. |
LED status indicators | Quickly understand unit and power status with visual indicators. |
Serial Connectivity | Provides management of the UPS via a serial port. |
USB connectivity | Provides management of the UPS via a USB port (not available on all models). |
Disconnected battery notification | Warns when a battery is not available to provide backup power. |
Serviceability | |
User-replaceable batteries | Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) |
Hot-swappable batteries | Ensures clean, uninterrupted power to protected equipment while batteries are being replaced |
Predictive failure notification | Provides early-warning fault analysis ensuring proactive component replacement. |
Resettable circuit breakers | Enables quick recovery from UPS overload events. |
Adaptability | |
Adjustable voltage-transfer points | Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. |
Adjustable voltage sensitivity | Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. |
Field-replaceable power distribution panel | Ensures compatibility with equipment that has different plug types. |
Safety | |
Safety-agency approved | Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals. |
Runtime Chart:
Click here to view the Smart-UPS Runtime Chart. (pop-up window)
Technical Specifications:
Output | |
Output Power Capacity | 1980 Watts / 2200 VA |
Max Configurable Power | 1980 Watts / 2200 VA |
Nominal Output Voltage | 120V |
Efficiency at Full Load | 98% |
Output Frequency (sync to mains) | 57 - 63 Hz for 60 Hz nominal |
Waveform Type | Sine wave |
Output Connections | (6) NEMA 5-15R (2) NEMA 5-20R |
Input | |
Nominal Input Voltage | 120V |
Input Frequency | 50/60 Hz +/- 3 Hz (auto sensing) |
Input Connections | NEMA 5-20P |
Cord Length | 8 feet (2.44 meters) |
Input voltage range for main operations | 82 - 144V |
Input voltage adjustable range for mains operation | 75 - 154V |
Batteries & Runtime | |
Battery Type | Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leakproof |
Typical recharge time | 3 hour(s) |
Replacement battery cartridge | RBC43 |
RBC™ Quantity | 1 |
Runtime Graph |
Curve fit to measured runtime data. All measurements taken with new, fully charged batteries, at typical environmental conditions, with no electrical input and balanced resistive load (PF = 1.0) output. |
Energy Use/Efficiency | |
Curve fit to measured runtime data. All measurements taken with new, fully charged batteries, at typical environmental conditions, with no electrical input and balanced resistive load (PF = 1.0) output. |
|
Communications & Management | |
Interface Port(s) | SmartSlot,USB |
Available SmartSlot™ Interface Quantity | 1 |
Control panel | LED status display with On Line : On Battery : Replace Battery and Overload indicators,Multi-function LCD status and control console |
Audible Alarm | Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
Surge Protection and Filtering | |
Surge Energy Rating | 530 Joules |
Physical | |
Maximum Height | 3.39 inches (86 mm) |
Maximum Width | 18.90 inches (480 mm) |
Maximum Depth | 26.89 inches (683 mm) |
Net Weight | 93.08 lbs. (42.31 kg) |
Shipping Weight | 109.41 lbs. (49.73 kg) |
Shipping Height | 10.00 inches (254 mm) |
Shipping Width | 23.62 inches (600 mm) |
Shipping Depth | 38.60 inches (980 mm) |
Rack Height | 2U |
Color | Black |
Units per Pallet | 8.00 |
Environmental | |
Operating Environment | 32 - 104°F (0 - 40°C) |
Operating Relative Humidity | 0 - 95% |
Operating Elevation | 0-10000 feet (0-3000 meters) |
Storage Temperature | 5 - 113°F (-15 - 45°C) |
Storage Relative Humidity | 0 - 95% |
Storage Elevation | 0-50000 feet (0-15000 meters) |
Audible noise at 1 meter from surface of unit | 55.00 dBA |
Online Thermal Dissipation | 215.00 BTU/hr |
Conformance | |
Regulatory Approvals | CSA, FCC Part 15 Class A, UL 1778 |
Standard Warranty | 3 years repair or replace (excluding battery) and 2 year for battery |
Equipment protection policy | Lifetime: $150,000 |
Environmental Compliance | RoHS 7b Exemption,REACH: Contains No SVHCs |