APC Smart-UPS Lithium-ion
The Smart-UPS™ you trust now offers 2x the battery life, saving you up to 50% on TCO. That’s Certainty in a Connected World.
Why APC Smart-UPS Lithium-ion?
2x UPS battery life
Lithium-ion UPS batteries are proven to offer double the effective lifecycle of lead-acid VRLA batteries. 8 to 10 years vs. 3 to 5 years.
Simpler, faster installation
Lithium-ion batteries are up to one-third lighter than VRLA, making installation simple.
Longer life in higher temperatures
Lithium-ion UPS batteries perform at ambient temperatures up to 104°F.
Remote UPS monitoring
Using a Network Management Card, APC SmartConnect** or EcoStruxure™ IT,** get anytime, anywhere visibility from any smart device.
Up to 50% TCO Savings
Increased UPS battery life reduces battery replacements and maintenance costs to save you up to 50% on TCO.
Perfect for tight spaces
Perfect for tight spaces At just 12 in depth our short-depth UPS fits conveniently into wall-mount racks and small closets.
APC Smart-UPS Li-Ion, Short Depth 500VA, 120V with Network Management Card
- Input Voltage- 120V
- Nominal Output Voltage- 120V
- Power Rated VA- 500
- Input Connection Type- NEMA 5-15P
- Output Connection Type- NEMA 5-15R
- Output Connection Count- 6
APC Smart-UPS Li-Ion, Short Depth 500VA, 120V with SmartConnect
- Input Voltage- 120 V
- Nominal Output Voltage- 120 V
- Power Rated VA- 500
- Input Connection Type- NEMA 5-15P
- Output Connection Type- NEMA 5-15R
- Output Connection Count- 6
APC Smart-UPS Li-Ion, Short Depth 750VA, 120V with SmartConnect
- Input Voltage- 120 V
- Nominal Output Voltage- 120 V
- Power Rated VA- 750
- Input Connection Type- NEMA 5-15P
- Output Connection Type- NEMA 5-15R
- Output Connection Count- 6
APC Smart-UPS Li-Ion, Short Depth 1000VA, 120V with SmartConnect
- Input Voltage- 120 V
- Nominal Output Voltage- 120 V
- Power Rated VA- 1000
- Input Connection Type- NEMA 5-15P
- Output Connection Type- NEMA 5-15R
- Output Connection Count- 6
APC Smart-UPS Li-Ion, Short Depth 1500VA, 120V with SmartConnect
- Input Voltage- 120 V
- Nominal Output Voltage- 120 V
- Power Rated VA- 1440
- Input Connection Type- NEMA 5-15P
- Output Connection Type- NEMA 5-15R
- Output Connection Count- 6
Lithium-ion UPS advantage
What is the right alternative to VRLA in your UPS? Smart-UPS with Lithium-ion batteries:
- Reduce costs with 2x the battery life
- Built-in Battery Management System
- Operate at higher temperatures without degradation
- Easy maintenance
- Five-year factory warranty on the UPS and battery
Lithium-ion UPS batteries versus VRLA
What are the benefits?
Lithium-ion batteries deliver higher-quality performance in a long-lasting package:
- Improved life expectancy of 3000 cycles (8 to 10 years) versus about 200 (3 to 5 years) for VRLA with improved resistance to discharge
- Lithium-ion batteries are >96% efficient in both charge and discharge
- Lithium-ion batteries are a more environmentally friendly technology
Features & Benefits:
Safety | |
Safety-agency approved | Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. |
Serviceability | |
Battery failure notification | Provides early-warning fault analysis on batteries enabling timely preventive maintenance |
User-replaceable batteries | Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) |
Hot-swappable batteries | Ensures clean, uninterrupted power to protected equipment while batteries are being replaced |
Predictive failure notification | Provides early-warning fault analysis ensuring proactive component replacement. |
Resettable circuit breakers | Enables a quick recovery from overload events. |
Adaptability | |
Adjustable voltage-transfer points | Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. |
Adjustable voltage sensitivity | Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. |
Availability | |
Intelligent battery management | Maximizes battery performance, life, and reliability through intelligent, precision charging. |
Power conditioning | Protects connected loads from surges, spikes, lightning, and other power disturbances. |
Boost and Trim Automatic Voltage Regulation (AVR) | Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models). |
Automatic restart of loads after UPS shutdown | Automatically starts up the connected equipment upon the return of utility power. |
Automatic self-test | Periodic battery self-test ensures early detection of a battery that needs to be replaced. |
Temperature-compensated battery charging | Prolongs battery life by regulating the charge voltage according to battery temperature. |
Disconnected battery notification | Warns when a battery is not available to provide backup power. |
Manageability | |
LED status indicators | Quickly understand unit and power status with visual indicators. |
Audible alarms | Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition. |
Network manageable | Provides remote power management of the UPS over the network. |
Disconnected battery notification | Warns when a battery is not available to provide backup power. |
USB connectivity | Provides management of the UPS via a USB port (not available on all models). |
Serial connectivity | Provides management of the UPS via a serial port. |