Call a Specialist Today! 800-223-3574

APC Symmetra LX 16kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output
APC Symmetra LX, 12.8 kW / 16 kVA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, Smart-Slot, Extended runtime model, Rack Height 19U

APC Symmetra LX 16kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

Includes: CD with software, Documentation CD, Installation guide, Rack Mounting support rails, Temperature Probe, User Manual, Web/SNMP Management Card

Looking for Better Pricing? Please Contact Us for help!

APC Products
APC Symmetra LX
APC Symmetra LX 16kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output
#SYA16K16RMP
Our Price: $32,125.00
Call For Lowest Price!

More pricing below, click here!

Industry’s most space-optimized modular UPS solutions

Engineered to deliver the highest level of business continuity possible, the Symmetra LX uses a modular, redundant architecture that can scale power and runtime as demand increases or when higher levels of availability are required. With built-in network manageability, and rack-optimized and tower models available from 4-16 kVA N+1 redundant, the online Symmetra LX is the choice to protect high-performance IT and Telecom equipment in business-critical server and network rooms. A flexible rack/stack design offers unmatched runtime and power capacity in space constrained environments. Symmetra LX allows incredibly fast upgrades and maintenance with virtually all of its parts contained in field-swappable components. These include hot-swappable, user-replaceable power, battery, and intelligence modules, management cards, LCD display, fans, and external battery frames. Additionally the wiring tray, frame electronics, receptacles, and casters can be swapped in minutes if necessary. Symmetra LX achieves industry-leading footprint or U-space needed in an equipment rack, increased speed and ease of deployment, and reduced repair time.

APC Symmetra LX 16kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output - Back View

Features & Benefits:

Availability
Modular design Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
Configurable for N+1 internal redundancy Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
Redundant Intelligence Modules Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.
Hot-swappable intelligence modules Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement.
Hot-swappable power modules Ensures clean, uninterrupted power to protected equipment during Power Module replacement.
Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Power Modules connected in parallel Enhances availability by allowing immediate, seamless recovery from isolated module failures.
Battery modules connected in parallel Delivers higher availability through redundant batteries.
Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.
Adaptability
Scalable power capacity Reduces UPS over-sizing costs today by allowing quick upgrades later.
Scalable runtime Allows additional run time to be quickly added as needed.
Plug-and-Play external batteries Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Rack/Tower convertible Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Field-replaceable power distribution panel Ensures compatibility with equipment that has different plug types.
Programmable frequency Ensures compatibility with different input frequencies.
Manageability
Manageable external batteries Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.
Network manageable Provides remote management of the UPS over the network.
InfraStruXure Manager compatible Enables centralized management via the APC InfraStruXure® Manager.
LCD display Alpha-Numeric Display which displays system parameters and alarms.
Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.
SmartSlot Customize UPS capabilities with management cards.
Serviceability
Shippable with modules installed Enables pre-installation UPS staging and testing and faster installation.
Predictive failure notification Provides early-warning fault analysis ensuring proactive component replacement.
Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Audible alarms Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
User-replaceable intelligence modules Enables simple upgrades and replacements of the Intelligence Modules.
User-replaceable power modules Enables simple upgrades and replacements of the Power Modules.
User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Disconnected battery notification Warns when a battery is not available to provide backup power.
Removable input/output wiring tray Allows quick and easy installation and maintenance of the UPS.
Protection
Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances.
Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling.
Generator compatible Ensures clean, uninterrupted power to the loads in the event of an extended power outage ;
Cold-start capable Provides temporary battery power when the utility power is out.
Resettable circuit breakers Enables a quick recovery from overload events.
Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals.

Product Views:

SYA16K16RMP Device Display

Device Display

SYA16K16RMP Device Rear Connection

Device Rear Connection

SYA16K16RMP Double Rack-Mount Device

Double Rack-Mount Device

SYA16K16RMP Device Rear Plug-in

Device Rear Plug-in

SYA16K16RMP Rack-Mount Device FrontSYA16K16RMP Rack-Mount Device Rear

Rack-Mount Device Front and Rear

Runtime Chart:

Click here for APC Symmetra LX Runtime chart. (pop-up window)

Technical Specifications:

Output
Output Power Capacity 12.8k W / 16k VA
Max Configurable Power 12.8k W / 16k VA
Nominal Output Voltage 120V, 208V
Output Voltage Note Configurable for 120/208 or 120/240 output voltage
Efficiency at Full Load 90%
Output Voltage Distortion Less than 5% at full load
Output Frequency (sync to mains) 47 - 63 Hz
Crest Factor up to 5 : 1
Waveform Type Sine wave
Output Connections (1) Hard Wire 4-wire (2PH + N +G)


NEMA L14-30R(4) NEMA L14-30R


NEMA L5-20R(8) NEMA L5-20R
Input
Bypass Internal Bypass (Automatic and Manual), Optional External Bypass
Nominal Input Voltage 208V
Input Frequency 45 - 65 Hz (auto sensing)
Input Connections Hard Wire 4-wire (2PH+N+G)
Input voltage range for main operations 96 - 138 (Line to Neutral)
Other Input Voltages 240V
Batteries & Runtime
Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leakproof
Included Battery Modules 4
Available Battery Slots -
Typical recharge time 3 hour (s)
Replacement battery cartridge SYBT5
Typical Backup Time at Half Load 17.1 minutes (4800 Watts)
Typical Backup Time at Full Load 6.0 minutes (9600 Watts)
Runtime Chart Symmetra LX
Extended Run Options APC Symmetra LX 16kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output
Energy Use/Efficiency
 

SYA16K16RMP Efficiency Graph

Curve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with nominal electrical input and resistive load output.

Communications & Management
Interface Port(s) DB-9 RS-232, Smart-Slot
Available SmartSlot™ Interface Quantity 1
Pre-Installed SmartSlot™ Cards AP9619
Control panel Multi-function LCD status and control console
Audible Alarm Audible and visible alarms prioritized by severity
Emergency Power Off (EPO) Yes
Physical
Maximum Height 32.90 inches (836 mm)
Maximum Width 18.60 inches (472 mm)
Maximum Depth 27.10 inches (688 mm)
Net Weight 631.00 lbs. (286.82 kg)
Shipping Weight 749.00 lbs. (340.45 kg)
Shipping Height 41.50 inches (1054 mm)
Shipping Width 23.60 inches (599 mm)
Shipping Depth 39.25 inches (997 mm)
Color Black, Silver
Units per Pallet 1.00
Rack Height 19U
Environmental
Operating Environment 32 - 104°F (0 - 40°C)
Operating Relative Humidity 0%
Operating Elevation 0-10000 feet (0-3000 meters)
Storage Temperature 5 - 113 °F (-15 - 45 °C)
Storage Relative Humidity 0%
Storage Elevation 0-15000 feet (0-4500 meters)
Audible noise at 1 meter from surface of unit 62.00 dBA
Online Thermal Dissipation 4995.00 BTU/hr
Conformance
Regulatory Approvals CSA,FCC Part 15 Class A,UL 1778
Standard Warranty 2 years repair or replace
**The time to recharge to 90% of full battery capacity following a discharge to shutdown using a load rated for 1/2 the full load rating of the UPS.

Pricing Notes:

Looking for Better Pricing? Please Contact Us for help!

APC Products
APC Symmetra LX
APC Symmetra LX 16kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output
#SYA16K16RMP
Our Price: $32,125.00
Call For Lowest Price!