AP8931

APC NetShelter Switched Rack PDU, 0U, 15A, 100-120V, 8 NEMA 5-15 outlets

AP8931

Includes: Installation guide, Rack Mounting brackets, Serial configuration cable, Safety guide

Looking for Better Pricing? Please Contact Us for help!

APC Products
APC NetShelter Switched Rack PDUs
APC NetShelter Switched Rack PDU, 0U, 15A, 100-120V, 8 NEMA 5-15 outlets
#AP8931
Our Price: $1,725.00

More pricing below, click here!

Overview

APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port and low profile circuit breakers. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.

  • Ideal for remote monitoring, reboots, powerup sequencing, scheduling power loads
  • Remote management of rack PDUs for efficient time-saving
  • Power sequencing delays determine the order in which power is turned on or off
  • 2 year warranty & Green PremiumTM label
  • Zero U toolless installation

Features & Benefits:

Adaptability

  • Wide range of input and output connections - Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 17.3kW using a single branch whip.
  • Rack-Mountable - Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
  • Single input power source - Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

Agility

  • Flash Upgradeable - Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)

Availability

  • 60C Operating Temperature - All 8000 and 9000 series PDUs now provide the ability to operate in a maximum ambient air temperature of 60C (140F) at full load ensuring reliability and availability even in today's high density deployments. Other models allow up to 45C (113F). C13/C15 and C19/C21 Hybrid Outlets - Available on select 9000 series PDUs only, Industry 1st hybrid outlets allow 60C operating temperature at full load, are fully compatible with standard C14 and C20 power cords, and are future proofed for implementation of higher temperature rated devices requiring C16 and C21 power cords.
  • Hydraulic Magnetic Circuit Breakers - Provide increased availability by maintaining trip current over a wide temperature range.
  • High Retention Outlets - With no special power cords required, high retention outlets provide up to twice the holding force to reduce risk of accidental disconnect on 9000 series PDUs.
  • Field-replaceable NMC - Integrated Network Management Card/Display Module can be replaced in the field to minimize downtime disruption in the unlikely event of a failure.

Manageability

  • Network Management Capabilities - Full-featured network management interfaces that provide standards-based management via Web and SNMP. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time.
  • Remote Individual Outlet Control - Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
  • Alarm Thresholds - Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
  • Multi-tier user access - Supports up to four access levels - Administrator, Device User, Read-Only User and Network-only User - with user name and password requirements.
  • Network Port Sharing - Connect and manage multiple PDUs from one IP address to simplify and speed deployment while saving the cost required in having a dedicated network connection for each PDU. Manage up to 32 PDUs with 9000 series and up to 4 PDUs with 8000 series.
  • Outlet Power Sequencing - Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
  • Alarm Thresholds - Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
  • Remote Management Capabilities - Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
  • 1% Metering Accuracy - Providing the same level of accuracy as a utility company meter by adhering to IEC 62053-21 class 1, 1% metering accuracy provides peace of mind to use these PDUs to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Available on 9000 series PDUs.
  • Enhanced Cybersecurity - 9000 series PDUs include APC Network Management card with security features including secured interfaces and a modified password policy providing peace of mind.
  • EcoStruxure IT Ready - Seamless integration of one or many PDUs including alerts and control with EcoStruxure IT. Allows IT and data center professionals to monitor and manage all of their critical IT infrastructure on-premise, in the cloud, and at the edge from anywhere.
  • Gigabit Ethernet Connectivity - 9000 series PDUs provide Gigabit Ethernet to enhance and standardize network connectivity across all assets in the data center. All other models provide 10/100 ethernet connectivity.
  • Outlet Level Grouping - Outlet power sequencing can be configured to group any combination of outlets to power up or down together providing flexibility.
  • Temperature/Humidity Monitoring Port - 8000 and 9000 series rack PDUs provide ability to monitor rack level temperature and humidity in conjunction with option temperature/humidity sensor.

Technical Specifications:

Main
Color Black
Product or Component Type PDU
PDU Type Switched
Cord length 9.8 ft (3 m)
Number of cables 1
Provided Equipment Installation guide
Rack Mounting brackets
Serial configuration cable
Safety guide
Complementary
Input Voltage 100 V
120 V
Height 38.9 in (988 mm)
Width 2.2 in (55 mm)
Output Voltage 100 V
120 V
Depth 1.8 in (46 mm)
Net Weight 9.17 lb(US) (4.16 kg)
Mounting Location Side
Mounting preference No preference
Input Plug Type NEMA 5-15P
Mounting Mode Rack-mounted
Rack units 0U
Mounting position Vertical
Line Rated Current 12 A
permissible voltage 100…120 V
Input current limits 15 A
Load Capacity 1440 VA
Input Frequency 50/60 Hz
Outlet type and quantity 8 NEMA 5-15R
Environment
Product Certifications cUL Listed
PSE
UL Listed
Standards FCC Part 15 class A
ICES-003
UL 60950-1
Ambient Air Temperature for Operation 23…140 °F (-5…60 °C)
Relative Humidity 5…95 %
Operating altitude 0...10000 ft
Ambient Air Temperature for Storage -13…149 °F (-25…65 °C)
Storage Relative Humidity 5…95 %
Storage altitude 0…50000 ft (0…15240 m)
Ordering and shipping details
GTIN 731304307525
Packing Units
Unit Type of Package 1 PCE
Nbr. of units in pkg. 1
Package 1 Height 44.5 in (113.1 cm)
Package 1 Width 4.26 in (10.83 cm)
Package 1 Length 6.3 in (16 cm)
Package weight(Lbs) 11.07 lb(US) (5.02 kg)
Contractual warranty
Warranty (in months) 24