Key Features:

  • Battery replacement without tools
  • Disconnected battery notification
  • Intelligent battery management
  • LED status indicators
  • Lifetime data recovery warranty

The most popular desktop UPS in the world!

APC's Back-UPS® ES series is now "greener" than ever. The ES 350 utilizes an ultra-efficient design that consumes less power during normal operation than any other battery backup in its class, saving you money on your electricity bill. It's also RoHS compliant, which means its manufacture and ultimate disposal is easier on the environment. Even the packaging has been carefully selected to minimize energy use in it's creation, and to maximize the use of recycled materials. Coupled with all the standard features of the Back-UPS ES series, the ES 350 is the best value for home and home office computers.

APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

Features & Benefits:

Features:
Battery failure notification Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Battery-protected and surge-only outlets Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment
Cold-start capable Provides temporary battery power when the utility power is out.
Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Disconnected battery notification Warns when a battery is not available to provide backup power.
Dataline Surge Protection Provides protection of connected equipment from power surges on the data lines.
Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Audible alarms Provides notification of changing utility power and UPS conditions.
User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Transformer-block spaced outlets Protect equipment with input transformer blocks without blocking access to other receptacles.
Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.
Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals.
Lifetime data recovery warranty Provides peace of mind by providing professional data recovery services in the event data is lost due to the failure of the unit.
Battery replacement without tools Allows quick, easy battery replacement.
LED status indicators Quickly understand unit and power status with visual indicators.

Runtime Chart:

120V
Watts 50 100 200 300 400 500 600 700 800 Full Half
VA~ 80 160 320 480 640 800 960 1120 1280 Load Load
BE350G 24 min 10 min 2 min - - - - - - 2 min (100 Watts) 9 min (200 Watts)
BE550G 1 hrs 5 mins 28 min 10 min 4 min - - - - - 3 min (330 Watts) 13 min (165 Watts)
BE650G 1 hrs 27 mins 38 min 15 min 7 min - - - - - 4 min (390 Watts) 15 min (195 Watts)
BE750G 1 hrs 25 mins 36 min 14 min 7 min 3 min - - - - 2 min (450 Watts) 11 min (225 Watts)

Technical Specifications:

Output
Output Power Capacity 200 Watts / 350 VA
Max Configurable Power 200 Watts / 350 VA
Nominal Output Voltage 120V
Output Frequency (sync to mains) 60 Hz
Waveform Type Stepped approximation to a sinewave
Output Connections NEMA 5-15R(3) NEMA 5-15R (Battery Backup)


NEMA 5-15R(3) NEMA 5-15R (Surge Protection)
Required Output Current Protection 15A
Input
Nominal Input Voltage 120V
Input Frequency 60 Hz +/- 1 Hz
Input Connections NEMA 5-15PNEMA 5-15P
Cord Length 5 feet (1.52 meters)
Input voltage range for main operations 88 - 139V
Batteries & Runtime
Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leakproof
Typical recharge time 16 hour(s)
Replacement battery cartridge RBC35
RBC™ Quantity 1
Typical Backup Time at Half Load 9.7 minutes (100 Watts)
Typical Backup Time at Full Load 2.3 minutes (200 Watts)
Runtime Chart Back-UPS ES
Communications & Management
Control Panel LED status display with On Line : On Battery : Replace Battery and Building Wiring Fault
Audible Alarm Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Surge Protection and Filtering
Surge Energy Rating 365 Joules
Filtering Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449
Dataline Protection RJ-45 Modem/Fax/DSL/10-100 Base-T protection,Co-axial Video / Cable protection
Physical
Maximum Height 3.50 inches (89 mm)
Maximum Width 6.25 inches (159 mm)
Maximum Depth 11.00 inches (279 mm)
Net Weight 8.00 lbs. (3.64 kg)
Shipping Weight 8.60 lbs. (3.91 kg)
Shipping Height 7.75 inches (197 mm)
Shipping Width 14.25 inches (362 mm)
Shipping Depth 5.00 inches (127 mm)
Master Carton Units 2.00
Master Carton Dimensions (Length x Width x Height) 15 x 11 x 8 inches (381 x 279 x 203 mm)
Master Carton Weight 17.50 lbs. (7.95 kg)
Color Charcoal
SCC Codes 107313042890 9
Units per Pallet 120.00
Environmental
Operating Environment 32 - 104°F (0 - 40°C)
Operating Relative Humidity 5 - 95%
Operating Elevation 0-10000 feet (0-3000 meters)
Storage Temperature 5 - 113°F (-15 - 45°C)
Storage Relative Humidity 5 - 95%
Storage Elevation 0-50000 feet (0-15000 meters)
Audible noise at 1 meter from surface of unit 45.00 dBA
Online Thermal Dissipation 15.00 BTU/hr
Conformance
Regulatory Approvals cUL Listed,FCC Part 15 Class B,FCC Part 68,NOM,UL 1778,UL 497A,UL 498
Standard Warranty 3 years repair or replace
Equipment protection policy Lifetime: $75,000